Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-34140840

RESUMO

PURPOSE: To revisit the "loopole," an unusual coil topology whose unbalanced current distribution captures both loop and electric dipole properties, which can be advantageous in ultra-high-field MRI. METHODS: Loopole coils were built by deliberately breaking the capacitor symmetry of traditional loop coils. The corresponding current distribution, transmit efficiency, and signal-to-noise ratio (SNR) were evaluated in simulation and experiments in comparison to those of loops and electric dipoles at 7 T (297 MHz). RESULTS: The loopole coil exhibited a hybrid current pattern, comprising features of both loops and electric dipole current patterns. Depending on the orientation relative to B0, the loopole demonstrated significant performance boost in either the transmit efficiency or SNR at the center of a dielectric sample when compared to a traditional loop. Modest improvements were observed when compared to an electric dipole. CONCLUSION: The loopole can achieve high performance by supporting both divergence-free and curl-free current patterns, which are both significant contributors to the ultimate intrinsic performance at ultra-high field. While electric dipoles exhibit similar hybrid properties, loopoles maintain the engineering advantages of loops, such as geometric decoupling and reduced resonance frequency dependence on sample loading.

2.
Magn Reson Med ; 80(5): 2267-2274, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29572959

RESUMO

PURPOSE: Transmit arrays are essential tools for various RF shimming or parallel excitation techniques at 7T. Here we present an array design with triangular coils to improve diversity in the B1 profiles in the longitudinal (z) direction and allow for next-nearest neighbor decoupling. METHODS: Two cylindrical 8-channel arrays having the same length and diameter, 1 of triangular coils and the other of rectangular coils, were constructed and compared in phantom imaging experiments using measures of excitation distribution for a variety of RF shim settings and geometry factor maps for different accelerations on different planes. RESULTS: Coupling between elements was -20 dB or better for all triangular coil pairs, but worse than -12 dB for several of the rectangular coil pairs. Both coils could produce adequate shims on a central transverse plane, but the same shim produced worse results off center for the triangular coil array than for the rectangular coil array. Compared to the rectangular coil array, the maximum geometry factor for the triangular coil array was reduced by a factor of 13.1 when using a 2-fold acceleration in the z-direction. CONCLUSION: An array design with triangular coils provides effective decoupling mechanisms for nearest and next-nearest neighboring elements, as well as diversity in B1 profiles along the z-direction, although this also means that individual slices must be shimmed separately. This design is well suited for parallel transmit applications while also having high receive sensitivity.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Razão Sinal-Ruído
3.
Magn Reson Med ; 79(3): 1789-1803, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28675512

RESUMO

PURPOSE: Previous work with body-size objects suggested that loops are optimal MR detectors at low fields, whereas electric dipoles are required to maximize signal-to-noise ratio (SNR) at ultrahigh fields ( ≥ 7 T). Here we investigated how many loops and/or dipoles are needed to approach the ultimate intrinsic SNR (UISNR) at various field strengths. METHODS: We calculated the UISNR inside dielectric cylinders mimicking different anatomical regions. We assessed the performance of various arrays with respect to the UISNR. We validated our results by comparing simulated and experimental coil performance maps. RESULTS: Arrays with an increasing number of loops can rapidly approach the UISNR at fields up to 3 T, but are suboptimal at ultrahigh fields for body-size objects. The opposite is true for dipole arrays. At 7 T and above, 16 dipoles provide considerably larger central SNR than any possible loop array, and minimal g factor penalty for parallel imaging. CONCLUSIONS: Electric dipoles can be advantageous at ultrahigh fields because they can produce both curl-free and divergence-free currents, whereas loops are limited to divergence-free contributions only. Combining loops and dipoles may be optimal for body imaging at 3 T, whereas arrays of loops or dipoles alone may perform better at lower or higher field strengths, respectively. Magn Reson Med 79:1789-1803, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Razão Sinal-Ruído
4.
Magn Reson Med ; 79(3): 1773-1780, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28631337

RESUMO

PURPOSE: To describe a new bench measurement based on quality (Q) factors to estimate the coil noise relative to the sample noise of dipole antennas at 7 T. METHODS: Placing a dipole antenna close to a highly conductive sample surrogate (HCSS) greatly reduces radiation loss, and using QHCSS gives a more accurate estimate of coil resistance than Qunloaded . Instead of using the ratio of unloaded and sample-loaded Q factors, the ratio of HCSS-loaded and sample-loaded Q factors should be used at ultra-high fields. A series of simulations were carried out to analyze the power budget of sample-loaded or HCSS-loaded dipole antennas. Two prototype dipole antennas were also constructed for bench measurements to validate the simulations. RESULTS: Simulations showed that radiation loss was suppressed when the dipole antenna was HCSS-loaded, and coil loss was largely the same as when the dipole was loaded by the sample. Bench measurements also showed good alignment with simulations. CONCLUSIONS: Using the ratio QHCSS /Qloaded gives a good estimate of the coil loss for dipole antennas at 7 T, and provides a convenient bench measurement to predict the body noise dominance of dipole antenna designs. The new approach also applies to conventional surface loop coils at ultra-high fields. Magn Reson Med 79:1773-1780, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Desenho de Equipamento/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Análise de Falha de Equipamento/métodos , Humanos , Imagens de Fantasmas
5.
Magn Reson Med ; 80(2): 822-832, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29250833

RESUMO

PURPOSE: To design a robust and patient friendly radiofrequency coil array (8-channel transmit and 16-channel receive) for cross-sectional body imaging at 7 T, and to improve our understanding of the combination of dipole and loop like elements for ultra high field strengths. METHODS: The hybrid coil array was optimized in eletromagnetic simulations. Considered array candidates were the dipole, loop and birdcage array. The winning design was constructed and the signal-to-noise (SNR) was compared to a close fitting array at 3 T. Transmit and receive properties for different body sizes were assessed, and multi-parametric maps were acquired with the Plug-and-Play MRF method. RESULTS: The winning design consists of a dipole array for transceive combined with a birdcage array for receive only. The central SNR improved by a factor of 3 as compared to a 3 T system with a local receive array. A transmit efficiency between 2.4 and 3.9 µT/kW, a specific absorption rate efficiency of 0.25 to 0.53 µT/W/kg, and a high SNR was achieved in the center for the targeted patient population. CONCLUSION: The constructed coil array is easy to handle, safe, and patient friendly, allowing further development of abdominal imaging at 7 T. Quantitative MRI in the abdomen is possible with Plug-and-Play MRF using the designed coil array. Magn Reson Med 80:822-832, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imagem Corporal Total/instrumentação , Abdome/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído , Imagem Corporal Total/métodos
6.
Magn Reson Med ; 80(1): 391-399, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29193307

RESUMO

PURPOSE: The aim of this study was to evaluate the effect of integrated high-permittivity materials (HPMs) on excitation homogeneity and global specific absorption rate (SAR) for transmit arrays at 7T. METHODS: A rapid electrodynamic simulation framework was used to calculate L-curves associated with excitation of a uniform 2D profile in a dielectric sphere. We used ultimate intrinsic SAR as an absolute performance reference to compare different transmit arrays in the presence and absence of a layer of HPM. We investigated the optimal permittivity for the HPM as a function of its thickness, the sample size, and the number of array elements. RESULTS: Adding a layer of HPM can improve the performance of a 24-element array to match that of a 48-element array without HPM, whereas a 48-element array with HPM can perform as well as a 64-element array without HPM. Optimal relative permittivity values changed based on sample and coil geometry, but were always within a range obtainable with readily available materials (εr = 100-200). CONCLUSION: Integration of HPMs could be a practical method to improve RF shimming performance, alternative to increasing the number of coils. The proposed simulation framework could be used to explore the design of novel transmit arrays for head imaging at ultra-high field strength. Magn Reson Med 80:391-399, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Algoritmos , Simulação por Computador , Desenho de Equipamento , Cabeça/diagnóstico por imagem , Humanos , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
7.
NMR Biomed ; 31(2)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29280204

RESUMO

The purpose of this work is to illustrate a new coil decoupling strategy and its application to a transmit/receive sodium/proton phased array for magnetic resonance imaging (MRI) of the human brain. We implemented an array of eight triangular coils that encircled the head. The ensemble of coils was arranged to form a modified degenerate mode birdcage whose eight shared rungs were offset from the z-axis at interleaved angles of ±30°. This key geometric modification resulted in triangular elements whose vertices were shared between next-nearest neighbors, which provided a convenient location for counter-wound decoupling inductors, whilst nearest-neighbor decoupling was addressed with shared capacitors along the rungs. This decoupling strategy alleviated the strong interaction that is characteristic of array coils at low frequency (32.6 MHz in this case) and allowed the coil to operate efficiently in transceive mode. The sodium array provided a 1.6-fold signal-to-noise ratio advantage over a dual-nuclei birdcage coil in the center of the head and up to 2.3-fold gain in the periphery. The array enabled sodium MRI of the brain with 5-mm isotropic resolution in approximately 13 min, thus helping to overcome low sodium MR sensitivity and improving quantification in neurological studies. An eight-channel proton array was integrated into the sodium array to enable anatomical imaging.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Prótons , Sódio/química , Simulação por Computador , Humanos , Razão Sinal-Ruído
8.
Artigo em Inglês | MEDLINE | ID: mdl-27795697

RESUMO

In high field MRI, the spatial distribution of the radiofrequency magnetic ( B1) field is usually affected by the presence of the sample. For hardware design and to aid interpretation of experimental results, it is important both to anticipate and to accurately simulate the behavior of these fields. Fields generated by a radiofrequency surface coil were simulated using dyadic Green's functions, or experimentally measured over a range of frequencies inside an object whose electrical properties were varied to illustrate a variety of transmit [Formula: see text] and receive [Formula: see text] field patterns. In this work, we examine how changes in polarization of the field and interference of propagating waves in an object can affect the B1 spatial distribution. Results are explained conceptually using Maxwell's equations and intuitive illustrations. We demonstrate that the electrical conductivity alters the spatial distribution of distinct polarized components of the field, causing "twisted" transmit and receive field patterns, and asymmetries between [Formula: see text] and [Formula: see text]. Additionally, interference patterns due to wavelength effects are observed at high field in samples with high relative permittivity and near-zero conductivity, but are not present in lossy samples due to the attenuation of propagating EM fields. This work provides a conceptual framework for understanding B1 spatial distributions for surface coils and can provide guidance for RF engineers.

9.
Nat Commun ; 7: 12445, 2016 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-27526996

RESUMO

Magnetic resonance imaging (MRI) has become an unrivalled medical diagnostic technique able to map tissue anatomy and physiology non-invasively. MRI measurements are meticulously engineered to control experimental conditions across the sample. However, residual radiofrequency (RF) field inhomogeneities are often unavoidable, leading to artefacts that degrade the diagnostic and scientific value of the images. Here we show that, paradoxically, these artefacts can be eliminated by deliberately interweaving freely varying heterogeneous RF fields into a magnetic resonance fingerprinting data-acquisition process. Observations made based on simulations are experimentally confirmed at 7 Tesla (T), and the clinical implications of this new paradigm are illustrated with in vivo measurements near an orthopaedic implant at 3T. These results show that it is possible to perform quantitative multiparametric imaging with heterogeneous RF fields, and to liberate MRI from the traditional struggle for control over the RF field uniformity.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Ondas de Rádio , Artefatos , Campos Eletromagnéticos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes
10.
NMR Biomed ; 29(2): 96-106, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26404631

RESUMO

(23)Na RF coil design for brain and MSK applications presents a number of challenges, including poor coil loading for arrays of small coils and SNR penalties associated with providing (1)H capability with the same coil. The basics of RF coil design are described, as well as a review of historical approaches to dual tuning. There follows a review of published high performance coil designs for MSK and brain imaging. Several coil designs have been demonstrated at 7T and 3T which incorporate close-fitting receive arrays and in some cases design features which provide (1)H imaging with little penalty to (23)Na sensitivity. The "nested coplanar loop" approach is examined, in which small transmit-receive (1)H elements are placed within each (23)Na loop, presenting only a small perturbation to (23)Na performance and minimizing RF shielding issues. Other designs incorporating transmit-receive arrays for (23)Na and (1)H are discussed including a 9.4 T (23)Na/(1)H brain coil. Great gains in (23)Na SNR have been made with many of these designs, but simultaneously achieving high performance for 1H remains elusive.


Assuntos
Encéfalo/anatomia & histologia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Sistema Musculoesquelético/anatomia & histologia , Ondas de Rádio , Sódio/metabolismo , Humanos
11.
Magn Reson Med ; 76(4): 1325-34, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26502310

RESUMO

PURPOSE: We describe a 2 × 6 channel sodium/proton array for knee MRI at 3T. Multielement coil arrays are desirable because of well-known signal-to-noise ratio advantages over volume and single-element coils. However, low tissue-coil coupling that is characteristic of coils operating at low frequency can make the potential gains from a phased array difficult to realize. METHODS: The issue of low tissue-coil coupling in the developed six-channel sodium receive array was addressed by implementing 1) a mechanically flexible former to minimize the coil-to-tissue distance and reduce the overall diameter of the array and 2) a wideband matching scheme that counteracts preamplifier noise degradation caused by coil coupling and a high-quality factor. The sodium array was complemented with a nested proton array to enable standard MRI. RESULTS: The wideband matching scheme and tight-fitting mechanical design contributed to >30% central signal-to-noise ratio gain on the sodium module over a mononuclear sodium birdcage coil, and the performance of the proton module was sufficient for clinical imaging. CONCLUSION: We expect the strategies presented in this study to be generally relevant in high-density receive arrays, particularly in x-nuclei or small animal applications. Magn Reson Med 76:1325-1334, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Cartilagem Articular/metabolismo , Glicosaminoglicanos/metabolismo , Articulação do Joelho/metabolismo , Imageamento por Ressonância Magnética/instrumentação , Imagem Molecular/instrumentação , Espectroscopia de Prótons por Ressonância Magnética/instrumentação , Isótopos de Sódio/farmacocinética , Biomarcadores/metabolismo , Cartilagem Articular/anatomia & histologia , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Articulação do Joelho/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
12.
Magn Reson Med ; 75(3): 1346-54, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25891292

RESUMO

PURPOSE: Development of a quantitative transverse relaxation time (T2)-mapping platform that operates at clinically feasible timescales by employing advanced image reconstruction of radially undersampled multi spin-echo (MSE) datasets. METHODS: Data was acquired on phantom and in vivo at 3 Tesla using MSE protocols employing radial k-space sampling trajectories. In order to overcome the nontrivial spin evolution associated with MSE protocols, a numerical signal model was precalculated based on Bloch simulations of the actual pulse-sequence scheme used in the acquisition process. This signal model was subsequently incorporated into an iterative model-based image reconstruction process, producing T2 and proton-density maps. RESULTS: T2 maps of phantom and in vivo brain were successfully constructed, closely matching values produced by a single spin-echo reference scan. High-resolution mapping was also performed for the spinal cord in vivo, differentiating the underlying gray/white matter morphology. CONCLUSION: The presented MSE data-processing framework offers reliable mapping of T2 relaxation values in a ∼ 5-minute timescale, free of user- and scanner-dependent variations. The use of radial k-space sampling provides further advantages in the form of high immunity to irregular physiological motion, as well as enhanced spatial resolutions, owing to its inherent ability to perform alias-free limited field-of-view imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Encéfalo/diagnóstico por imagem , Simulação por Computador , Humanos , Imagens de Fantasmas
13.
J Magn Reson Imaging ; 41(1): 226-32, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24259458

RESUMO

PURPOSE: To report design of a simplified external transmit-receive coil array for 7 Tesla (T) prostate MRI, including demonstration of the array for tumor localization using T2-weighted imaging (T2WI) at 7T before prostatectomy. MATERIALS AND METHODS: Following simulations of transmitter designs not requiring parallel transmission or radiofrequency-shimming, a coil array was constructed using loop elements, with anterior and posterior rows comprising one transmit-receive element and three receive-only elements. This coil structure was optimized using a whole-body phantom. In vivo sequence optimization was performed to optimize achieved flip angle (FA) and signal to noise ratio (SNR) in prostate. The system was evaluated in a healthy volunteer at 3T and 7T. The 7T T2WI was performed in two prostate cancer patients before prostatectomy, and localization of dominant tumors was subjectively compared with histopathological findings. Image quality was compared between 3T and 7T in these patients. RESULTS: Simulations of the B1(+) field in prostate using two-loop design showed good magnitude (B1(+) of 0.245 A/m/w(1/2)) and uniformity (nonuniformity [SD/mean] of 10.4%). In the volunteer, 90° FA was achieved in prostate using 225 v 1 ms hard-pulse (indicating good efficiency), FA maps confirmed good uniformity (14.1% nonuniformity), and SNR maps showed SNR gain of 2.1 at 7T versus 3T. In patients, 7T T2WI showed excellent visual correspondence with prostatectomy findings. 7T images demonstrated higher estimated SNR (eSNR) in benign peripheral zone (PZ) and tumor compared with 3T, but lower eSNR in fat and slight decreases in tumor-to-PZ contrast and PZ-homogeneity. CONCLUSION: We have demonstrated feasibility of a simplified external coil array for high-resolution T2-weighted prostate MRI at 7T.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Adulto , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Próstata/patologia , Próstata/cirurgia , Razão Sinal-Ruído
14.
J Magn Reson Imaging ; 39(3): 540-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24123517

RESUMO

PURPOSE: To develop a bilateral coil and fat suppressed T1-weighted sequence for 7 Tesla (T) breast MRI. MATERIALS AND METHODS: A dual-solenoid coil and three-dimensional (3D) T1w gradient echo sequence with B1+ insensitive fat suppression (FS) were developed. T1w FS image quality was characterized through image uniformity and fat-water contrast measurements in 11 subjects. Signal-to-noise ratio (SNR) and flip angle maps were acquired to assess the coil performance. Bilateral contrast-enhanced and unilateral high resolution (0.6 mm isotropic, 6.5 min acquisition time) imaging highlighted the 7T SNR advantage. RESULTS: Reliable and effective FS and high image quality was observed in all subjects at 7T, indicating that the custom coil and pulse sequence were insensitive to high-field obstacles such as variable tissue loading. 7T and 3T image uniformity was similar (P=0.24), indicating adequate 7T B1+ uniformity. High 7T SNR and fat-water contrast enabled 0.6 mm isotropic imaging and visualization of a high level of fibroglandular tissue detail. CONCLUSION: 7T T1w FS bilateral breast imaging is feasible with a custom radiofrequency (RF) coil and pulse sequence. Similar image uniformity was achieved at 7T and 3T, despite different RF field behavior and variable coil-tissue interaction due to anatomic differences that might be expected to alter magnetic field patterns.


Assuntos
Mama/patologia , Meios de Contraste , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Adulto , Neoplasias da Mama/diagnóstico , Estudos de Coortes , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Adulto Jovem
15.
Invest Radiol ; 49(1): 35-47, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24056112

RESUMO

OBJECTIVE: The objective of the study was to investigate the feasibility of 7-T shoulder magnetic resonance imaging by developing transmit and receive radiofrequency (RF) coil arrays and exploring RF shim methods. MATERIALS AND METHODS: A mechanically flexible 8-channel transmit array and an anatomically conformable 10-channel receive array were designed and implemented. The transmit performance of various RF shim methods was assessed through local flip angle measurements in the right and left shoulders of 6 subjects. The receive performance was assessed through signal-to-noise ratio measurements using the developed 7-T coil and a baseline commercial 3-T coil. RESULTS: The 7-T transmit array driven with phase-coherent RF shim weights provided adequate B1⁺ efficiency and uniformity for turbo spin echo shoulder imaging. B1⁺ twisting that is characteristic of high-field loop coils necessitates distinct RF shim weights in the right and left shoulders. The 7-T receive array provided a 2-fold signal-to-noise ratio improvement over the 3-T array in the deep articular shoulder cartilage. CONCLUSIONS: Shoulder imaging at 7-T is feasible with a custom transmit/receive array either in a single-channel transmit mode with a fixed RF shim or in a parallel transmit mode with a subject-specific RF shim.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Ombro/anatomia & histologia , Processamento de Sinais Assistido por Computador/instrumentação , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Eur Radiol ; 23(11): 2969-78, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23896763

RESUMO

OBJECTIVES: To evaluate the image quality of T1-weighted fat-suppressed breast MRI at 7 T and to compare 7-T and 3-T images. METHODS: Seventeen subjects were imaged using a 7-T bilateral transmit-receive coil and 3D gradient echo sequence with adiabatic inversion-based fat suppression (FS). Images were graded on a five-point scale and quantitatively assessed through signal-to-noise ratio (SNR), fibroglandular/fat contrast and signal uniformity measurements. RESULTS: Image scores at 7 and 3 T were similar on standard-resolution images (1.1 × 1.1 × 1.1-1.6 mm(3)), indicating that high-quality breast imaging with clinical parameters can be performed at 7 T. The 7-T SNR advantage was underscored on 0.6-mm isotropic images, where image quality was significantly greater than at 3 T (4.2 versus 3.1, P ≤ 0.0001). Fibroglandular/fat contrast was more than two times higher at 7 T than at 3 T, owing to effective adiabatic inversion-based FS and the inherent 7-T signal advantage. Signal uniformity was comparable at 7 and 3 T (P < 0.05). Similar 7-T image quality was observed in all subjects, indicating robustness against anatomical variation. CONCLUSION: The 7-T bilateral transmit-receive coil and adiabatic inversion-based FS technique produce image quality that is as good as or better than at 3 T. KEY POINTS: • High image quality bilateral breast MRI is achievable with clinical parameters at 7 T. • 7-T high-resolution imaging improves delineation of subtle soft tissue structures. • Adiabatic-based fat suppression provides excellent fibroglandular/fat contrast at 7 T. • 7- and 3-T 3D T1-weighted gradient-echo images have similar signal uniformity. • The 7-T dual solenoid coil enables bilateral imaging without compromising uniformity.


Assuntos
Doenças Mamárias/diagnóstico , Mama/patologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/instrumentação , Tecido Adiposo/patologia , Adulto , Diagnóstico Diferencial , Desenho de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
17.
Schizophr Res ; 147(2-3): 362-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23664589

RESUMO

PURPOSE: The hippocampus is central to the pathophysiology of schizophrenia. Histology shows abnormalities in the dentate granule cell layer (DGCL), but its small size (~100 µm thickness) has precluded in vivo human studies. We used ultra high field magnetic resonance imaging (MRI) to compare DGCL morphology of schizophrenic patients to matched controls. METHOD: Bilateral hippocampi of 16 schizophrenia patients (10 male) 40.7 ± 10.6 years old (mean ± standard deviation) were imaged at 7 Tesla MRI with heavily T2*-weighted gradient-echo sequence at 232 µm in-plane resolution (0.08 µL image voxels). Fifteen matched controls (8 male, 35.6 ± 9.4 years old) and one ex vivo post mortem hippocampus (that also underwent histopathology) were scanned with same protocol. Three blinded neuroradiologists rated each DGCL on a qualitative scale of 1 to 6 (from "not discernible" to "easily visible, appearing dark gray or black") and mean left and right DGCL scores were compared using a non-parametric Mann-Whitney test. RESULTS: MRI identification of the DGCL was validated with histopathology. Mean right and left DGCL ratings in patients (3.2 ± 1.0 and 3.5 ± 1.2) were not statistically different from those of controls (3.9 ± 1.1 and 3.8 ± 0.8), but patients had a trend for lower right DGCL score (p = 0.07), which was significantly associated with patient diagnosis (p = 0.05). The optimal 48% sensitivity and 80% specificity for schizophrenia were achieved with a DGCL rating of ≤2. CONCLUSION: Decreased contrast in the right DGCL in schizophrenia was predictive of schizophrenia diagnosis. Better utility of this metric as a schizophrenia biomarker may be achieved in future studies of patients with homogeneous disease subtypes and progression rates.


Assuntos
Giro Denteado/patologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Esquizofrenia/diagnóstico , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas , Adulto Jovem
18.
J Neurosurg Pediatr ; 11(3): 268-73, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23289918

RESUMO

OBJECT: Tuberous sclerosis complex (TSC) brain pathology is characterized on MRI by cortical tubers, subependymal nodules, and subependymal giant cell astrocytomas. Seizures, the prominent feature of TSC, are frequently intractable to medical therapy and, in many patients, resection of tubers results in seizure control. However, in approximately 40% of patients, resection of tubers does not control seizures. This fact, as well as evidence from invasive electrophysiological recordings and experimental animal models, suggests that in patients with TSC, there may be extratuberal epileptogenic brain that does not display any apparent abnormality on conventional MRI. The authors hypothesized that high field strength MRI might uncover lesions not seen on conventional MRI in these patients. METHODS: Institutional review board approval was obtained to scan 4 patients with TSC (ages 18-26 years) in a 7-T MR unit. Optimized 7-T sequences, including T1- and T2-weighted, FLAIR, SPACE FLAIR, T2*, and MPRAGE studies, were performed. Imaging studies were compared with identical sequences performed using a conventional 1.5-T MR scanner. RESULTS: In all 4 patients, there was improved visualization of the findings demonstrated on conventional imaging. Importantly, new lesions were detected in all 4 patients, which were not well visualized with conventional MRI. Newly detected lesions included microtubers, radial glial signal abnormalities, subependymal nodules arising from the caudate nucleus, and caudate nucleus lesions. CONCLUSIONS: High field strength MRI detects previously uncharacterized lesions in patients with TSC and allows better detection and delineation of subtle abnormalities. In addition, the data demonstrate a compelling relationship between intraventricular lesions and the caudate nucleus. These data support previous electrophysiological and animal-model findings that demonstrate neurological pathology beyond the conventionally detected lesions in TSC.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Esclerose Tuberosa/patologia , Adolescente , Adulto , Idade de Início , Astrocitoma/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Convulsões/etiologia , Esclerose Tuberosa/complicações , Adulto Jovem
19.
Magn Reson Med ; 70(1): 259-68, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22887123

RESUMO

The critical design aim for a sodium/proton coil is to maximize sodium sensitivity and transmit field homogeneity while simultaneously providing adequate proton sensitivity and homogeneity. While most dual-frequency coils use lossy high-impedance trap circuits or PIN diodes to allow dual-resonance, we explored a nested-coil design for sodium/proton knee imaging at 7 T. A stand-alone eight-channel sodium receive array was implemented without standard dual-resonance circuitry to provide improved sodium signal-to-noise ratio. A detunable sodium birdcage was added for homogeneous sodium excitation and a four-channel proton transmit-receive array was added to provide anatomical reference imaging and B0 shimming capabilities. Both additional modules were implemented with minimal disturbance to the eight-channel sodium array by managing their respective resonances and geometrical arrangement. In vivo sodium signal-to-noise ratio was 1.2-1.7 times greater in the developed eight-channel array than in a mononuclear sodium birdcage coil, whereas the developed four-channel proton array provided signal-to-noise ratio similar to that of a commercial mononuclear proton birdcage coil.


Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/química , Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Sódio/análise , Algoritmos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Prótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
NMR Biomed ; 26(1): 9-19, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22714793

RESUMO

In vivo sodium magnetic resonance imaging (MRI) measures tissue sodium content in living human brain but current methods do not allow noninvasive quantitative assessment of intracellular sodium concentration (ISC) - the most useful marker of tissue viability. In this study, we report the first noninvasive quantitative in vivo measurement of ISC and intracellular sodium volume fraction (ISVF) in healthy human brain, made possible by measuring tissue sodium concentration (TSC) and intracellular sodium molar fraction (ISMF) at ultra-high field MRI. The method uses single-quantum (SQ) and triple-quantum filtered (TQF) imaging at 7 Tesla to separate intra- and extracellular sodium signals and provide quantification of ISMF, ISC and ISVF. This novel method allows noninvasive quantitative measurement of ISC and ISVF, opening many possibilities for structural and functional metabolic studies in healthy and diseased brains.


Assuntos
Algoritmos , Encéfalo/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Sódio/metabolismo , Adulto , Idoso , Simulação por Computador , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...